interplane.Get Omega
Read in your language

aien-sovereign-core-mv

AienOS host runtime: inference scheduling, paged KV state, the aien CLI and Spark verification tooling. Its inference engine is in alpha testing (DGX Spark GB10); Omega is the implementation destination.

Brought by drakestapleton

branch main Branches Tags History

aien-sovereign-core-mv / docs / campaigns / whole-system-e2e / runs / RUN-7-CPU-20261011T144128Z / ACCEPTANCE-v1.6-logical-workspace.as-run.md

81 lines · 6264 bytes Raw Blame History Source

WHOLE-SYSTEM-E2E, harness v1.6: the logical workspace prompt baseline (RUN-7-CPU and RUN-7-GB10)

Tracking: aien-spark/aien-sovereign-core#402 (R6, owning issue), #429 (product issue), #431 (product fix), aien-spark/aien-architecture#190 (Drake ruling D2, 2026-10-11). Contract: ACCEPTANCE_E2E.md FROZEN at aien-architecture b2400fe, sha256 9e3d5f4e23d65ac17be8f2f4ca48355f0aaa486f67ff5a8a8044dcdd646d34e8. This file is committed before any run under the changed product. ACCEPTANCE-v1.md to -v1.5-fixed-root.md stay as written; RUN-1 to RUN-6 stay as recorded. No row, rule, score, threshold, objective text or input changes. The harness script is not changed by this version.

Disclosure: written after RUN-6 and after the product fix

RUN-6-GB10 (RESULT-RUN-6-GB10.md) failed E3 (D4) and E4 under the fixed run root of v1.5. The ruling recorded there was: no further R6 attempt without a pre-registered input change. Drake's decision D2 (arch#190, 2026-10-11) approved the product change #429: the model-visible proposal prompt names the workspace by the constant label workspace (spine::WORKSPACE_LABEL, PR #431) instead of the machine-specific absolute path. The real path stays in the authorization, confinement, execution and evidence layers. This is a product change, not a harness control: it changes every model input on the compose path, so every prompt id and every greedy output recorded in RUN-1 to RUN-6 is a different baseline from the one measured here. Those runs are historical evidence and are not re-judged.

The label workspace was chosen as a plain constant before any model input under it was built or run. It was NOT chosen by comparing model outputs under candidate labels; choosing a label because its output passes is selecting on outcome and is forbidden. The E3, E3m and E4 prompt token counts and prompt_ids_sha256 under the new prompt are UNKNOWN at declaration.

The control

  1. Product under test: the merged main commit that contains #431. The PRE receipt already records the product commit and the pins; the result names the commit.
  2. Prompt independence, proven before the run: at that commit, `cargo test -p aien-runtime --test logical_workspace_testis run withAIEN_TOKENIZER_PATH` set to the CAND-4 tokenizer (Llama 3.2 1B Instruct) and its output is kept in the run folder as logical_workspace_test.txt. It must show 2 passed (equal prompts and equal token ids for two workspaces at different absolute paths). A failure stops the attempt before any daemon starts.
  3. Run root: WSE2E_RUN_ROOT=/home/drakestapleton/.aien-e2e/run as v1.5. It no longer enters the prompt; it is kept so that the evidence paths of RUN-6 and RUN-7 compare directly.
  4. Recorded prompt ids: rows E3, E3m and E4 record prompt_attempts (prompt_tokens, prompt_ids_sha256) as v1.5. Recording only; no row is judged on them. The result lists them as the new baseline values.
  5. Negative control (recorded, not judged): after the run, the CPU reconstruction of the E3 model input with the product's own functions (persona block, spine::task_prompt, chat template, compose assistant prefix, model tokenizer), performed as in RESULT-RUN-5-GB10.md, is built twice: once under the run root and once under a throwaway folder with a different name and depth. The two prompt_ids_sha256 must be equal and must equal the id the run recorded for E3 attempt 1. Inequality is reported as a harness or product defect, never hidden.
  6. A copy of this file is written by hand into each run folder as ACCEPTANCE-v1.6-logical-workspace.as-run.md (the harness copies v1.5; this version adds no harness code).

The two declared runs

runmodepurpose
RUN-7-CPUWSE2E_BACKEND=cputhe new CPU whole-system baseline for the logical-workspace prompt (replaces RUN-1 as the reference input set for later R7 cross-machine comparison; RUN-1 stays as recorded)
RUN-7-GB10WSE2E_BACKEND=gb10the R6 GB10 qualification under the changed product, attempt 5 (RUN-2, RUN-3, RUN-5 and RUN-6 named as earlier attempts)

Order: RUN-7-CPU first, then RUN-7-GB10. One declared attempt each. An outcome stands; neither run is repeated to find a passing input.

Predictions (written before either run)

rowpredictionwhy
PRE, CTRL-E3a, E2, CTRL-E2, E6, CTRL-E3b, NET, CTRL-E6, CTRL-E4PASSPASS in RUN-5 and RUN-6 with fallback 0; nothing here reads the prompt text
E3PASS or FAIL as measuredUNVERIFIED: the 1B model's E3 text under the new prompt has never been generated; no outcome is predicted
E3mPASS or FAIL as measuredsame; PASS in RUN-3, RUN-5 and RUN-6 under the old prompt
E4PASS or FAIL as measuredFAIL in RUN-6 (edit reply unchanged), PASS in RUN-5; depends on the prompt text
CTRL-E5PASS if E3 PASS, else FAIL as a consequenceas RUN-3, RUN-5 and RUN-6
CTRL-E4bRECORDEDnot judged (v1.2)
E1, E5, CTRL-E1NOT_RUNsource-build modes; R8 (install) and R7 (second machine)
G4, G5 (gb10 only)fallback_detected: false; every model-calling row gpu_executions >= 1as RUN-3, RUN-5 and RUN-6

Rules of these runs

As ACCEPTANCE-v1.5-fixed-root.md: from the merged main commit that contains #431 and this file, folders runs/RUN-7-CPU-<utc>/ and runs/RUN-7-GB10-<utc>/, WSE2E_RUN_ROOT=/home/drakestapleton/.aien-e2e/run (the RUN-6 state moved aside by the harness), started detached, never killed, quietlock check first, the chip free of other runs for the gb10 run, nothing under runs/ edited afterwards. If a row fails, that outcome stands and the next step is a pre-registered input change (model decision D1 or a product issue), never a rerun under this control. No program PASS is claimed by any outcome of these runs: R6 PASS requires every required row of the frozen contract; R8 stays blocked on the real signing key, the qualified public model and the CAND-5 pins.

Not part of this control

The public model (Drake D1: Qwen3-8B evaluation and a frozen v7 campaign), the release signing ceremony (D3), the install run (R8) and the native AIENOS work (D4) are separate lanes with their own pre-registered controls.