This came out of the post-merge review of #470: https://github.com/aien-dev/aienux/pull/470#pullrequestreview-5712051369 (finding 5).
Problem: nothing in the probe ever calls ck_dma_faults. So when a stream can't be aborted (ck_dma_unconfine fails and the release takes the release-failed path), the SMMU fault events from that stream are never drained or logged. The release fails safe: the stream stays confined and the device stays owned. But the console shows nothing about what the device was trying to do while it was stuck. The updated B7B-PHYSICAL-BOOT-PREP.md already notes this gap.
Expected: on the release-failed path (NVMe, net and xHCI release), drain the SMMU fault queue for the affected stream once and log what it holds, so a failed release leaves evidence behind.
Done when:
- Each release-failed path drains and logs the SMMU fault events once, without changing the fail-closed behaviour (the stream stays confined, the device stays owned, and later bind or fence attempts are still refused).
- A host test using the existing
ck_host_unconfine_failmock, plus a fault-queue mock if needed, shows that faults are drained and logged on a failed release. - Draining doesn't free or reuse the stream's DMA buffers while it is still confined (see finding 3 in the same review).
- CI is green.
Related: #478, the xHCI platform fallback that reports success after a failed release.
Not verified on hardware: real SMMU fault-queue behaviour on Spark/GB10 and other boards is hardware-unverified.