EST-2/EST-3 protocol v1: tool readings
Companion to EST23_PROTOCOL_V1.md (frozen at commit f96dc97, not edited). It
records how the tools read the places where the protocol text can be read more
than one way. No threshold, band, grid value or model is weakened or changed.
- Step 0 is the first valid line. It is the prior, and burn-in excludes every step with L < 30, where L counts from that prior line (L = 0 is the prior). So 29 innovations are dropped after the prior.
- Horizon rounds the wall-clock gap half up: (gap + 0.5 s) / 1 s in integer
arithmetic, minimum 1. A gap of zero or less (duplicate or backward
t) gives horizon 1. Those cases are counted in the receipt. - Every line after the prior gets one step.
- A missing observation coasts with a zero observation digest and is excluded
from every statistic, including ten-step origins. A line whose
tfails to parse is a missing observation even when its value parses. A seconds field longer than 10 digits, or one that would overflow 64-bit nanoseconds, is atparse failure and is counted separately. thermal_mcmust be a plain decimal. Hex, nan and inf are missing.- Ten-step coverage uses logical time and the horizon-10 predicted variance. Origins that were coasted are skipped; targets must be non-coasted steps.
- Quarters split the included samples by logical time into four equal spans.
- Lag-1 autocorrelation and Ljung-Box run over included, non-coasted innovations, using the sample mean.
- Standardized bias uses the n-1 standard deviation.
- The persistence baseline is the previous valid observation, over the same included steps.
- CALIBRATION PASS means some model is calibrated with RMSE no worse than persistence.
- Extra reported statistic: the fraction of exactly-zero innovations.
- An unclosed
beginin the marks file runs to the end of the file and is reported in the receipt, together with begin, end, nested-begin and stray-end counts.
These readings were fixed before any run on run B; they change no band, grid value or model.