ESTIMATION v5: result HELD_OUT_FAIL (selected G1 not calibrated on D2)
Verdict: ESTIMATION_CALIBRATION (v5) = HELD_OUT_FAIL, reason "S not calibrated",
first failing statistic pit_bin0. Receipt: receipt-7f0bb7018d066bc438e7a8a9bf87c0d45615f60be2d029b6ab5194168e3db3d1.json
(tool commit eec20d2, tool_dirty 0, synthetic_test false). Scored once on
2026-10-05; the tool refuses a second receipt. EST-3 stays FAILED (v1 to v3), v4 stays
INCONCLUSIVE, and EST-4 and EST-5 stay blocked.
Protocol: docs/estimation/protocols/est-v5.md, sha256
275cd5b72570d5182ef73d635e16775026e9d911e818b8e12f8300a701187af5, frozen at
b37e34b, unchanged. Params sha256 6be2b579980f22b48d8224b36dec39b6154cc82c15a85979291672b2c5c2aa3a,
unchanged since D1. No threshold, rule, tool or parameter was changed after D2 was collected.
D1 collection
| Attempt | Seed | Window | Outcome |
|---|---|---|---|
| 1 | 0xE5C5D1 | 111 foreign samples (cargo, rustc, make, cc, test_osc_backend) 15:01:57 to 15:07:32Z although the quiet flag was held | void, aborted at 15:31Z after 1824 s, never fitted or scored (evidence/EST5/raw/20261001T150104Z-est5-fit-silicon/, INVALID) |
| 2 | 0xE5C5D2 | WINDOW_CLEAN samples=1317 foreign=0, 15:31:56 to 16:17:07Z | used as D1 (evidence/EST5/raw/20261001T153156Z-est5-fit-silicon/) |
Attempt 1 was voided on the process monitor alone (protocol section 7), before any
thermal value was read. The cause is that the quiet-guard hook only reaches sessions
and commands that load it; the coordinator then stopped every lane and attempt 2 saw
no foreign build, test or gate process (process-monitor.log in the folder, 0
FOREIGN lines; WINDOW file; both in SHA256SUMS). The v3 pre-check on D1 is
VALID (2682 lines, 0 of 2681 gaps above 1.5 s, marks ok, foreign mean 0.2787 busy
cores, 0 samples above 3.0, 0 unmeasured). The only informational HIGHCPU lines
were other sessions' interpreters, not builds or tests.
D2 collection (sealed held-out)
| Attempt | Seed | Window | Outcome |
|---|---|---|---|
| 1 | 0xD2E5C6 | WINDOW_CLEAN samples=1312 foreign=0, 11:28:38 to about 12:14Z on 2026-10-05 | used as D2 (evidence/EST5/raw/20261005T112838Z-est5-heldout-silicon/) |
Before collection every other session on the machine confirmed it had stopped builds,
tests, QEMU and GPU work, and both idle clangd language servers were stopped (the
collector refused its first start because of them; that refusal collected nothing).
Quiet flag held by L10-EST5D2 for the window. Raw files committed with d2.sha256 in
eec20d2 before scoring. Pre-check: VALID (2681 lines, 0 of 2680 gaps above 1.5 s,
marks ok, foreign mean 0.4138 busy cores, 0 samples above 3.0, 0 unmeasured).
D2 score (the one binding run, est5 recorded)
| Family | D2 one-step mean log score | Calibrated on D2 |
|---|---|---|
| G1 lag (selected) | -1.80307 | no (first fail pit_bin0) |
| E0 baseline | -2.10541 | no |
| F1 baseline | -2.97852 | no |
G1 beat both baselines (same steps, tie allowance 0.01 nats) and passed 22 of its 23 gated statistics on 2651 scored steps: coverage50 0.533 (band 0.46 to 0.54), coverage80 0.822 (0.76 to 0.84), coverage95 0.953 (0.93 to 0.97), PIT bins 1 to 9 inside 0.07 to 0.13, and the quarter, regime, ten-step, bias and lag-1 checks. It failed one: PIT bin 0 = 0.0681, below the lower bound 0.07. That bin holds steps where the real temperature fell in the lowest tenth of the forecast range; too few of them means the forecast puts slightly too much weight on low temperatures (a low tail a little too wide, or forecasts a little low; the run does not say which). Under section 6 a single failed gated statistic means not calibrated, so the verdict is HELD_OUT_FAIL. The margin is small and is recorded here only as description; it does not change the verdict.
Phase A (the one binding fit, est5 fit, params sha256 6be2b579980f22b48d8224b36dec39b6154cc82c15a85979291672b2c5c2aa3a)
phase_a PASS, selected G1 (all three families pass the in-sample screen on 2652
scored steps).
| Family | D1 one-step log score | D1 ten-step log score | Screen |
|---|---|---|---|
| G1 lag | -1.96281 | -3.72398 | pass |
| G2 AR change | -1.96411 | -3.71924 | pass |
| G3 two-tank | -1.97846 | -3.62463 | pass |
| F1 baseline | -2.94238 |
G1 parameters: tau 1 s, q 1e4, lambda 0.1 (on the grid edge, flagged only), nu 1.25, c 0.7, phi 0.95, nu_h 0.8, c_h 0.2. These numbers are in-sample and carry no held-out meaning.
Limits (read before quoting any v5 outcome)
The following is the external statistical review (Astra, via OpenCode; Grok was unavailable, out of credit; Gemini agreed the estimator is sound and proposed model changes that v5 does not adopt), quoted:
The proposed PASS is meaningful as a predeclared operational acceptance check, but it is not a statistically established certificate of calibration. Its overall false-pass and false-fail rates are unknown.
The important result is that a nominal 95% interval that actually covers 92% can pass about 88% of the time. Its miss rate is 8% instead of 5%, which is 60% more misses than advertised.
A clean PASS under the present rules would license this claim: On this new run from the specified workload generator, the frozen forecasting procedure met our declared accuracy, coverage, and comparison thresholds. It would not yet license "statistically validated 95% calibration," a known overall false-pass rate, physically identified thermal parameters, or safety guarantees.
Further limits recorded from that review: mid-PIT z checks (bias, lag-1) are descriptive on a discrete predictive; the F1 comparison has no sampling allowance; the result covers new schedules of the same load generator only (not other workloads, ambient conditions, boards or horizons beyond 1 and 10 s).
Downstream