omega-mv
Omega: a language for verified programs, semantic identity and machine realization. Seed-born work and existing implementations have distinct provenance.
Brought by drakestapleton
omega-mv / docs / estimation / receipts / est23-v1 / RESULT.md
| 1 | # EST-3 protocol v1: recorded result (2026-09-30) |
| 2 | |
| 3 | One recorded execution on held-out run B (`20260929T025735Z-3e9e53be3358-silicon`), tool commit 44f591b, protocol f96dc97, parameters fitted on run A only (`params.txt`). No rerun. `receipt.json` and both step streams sit beside this file. |
| 4 | |
| 5 | ```text |
| 6 | ESTIMATION_REAL_SIGNAL = PASS (replay complete, prefix invariance, raw unchanged, chain recorded for all 2009 steps) |
| 7 | ESTIMATION_CALIBRATION = FAIL (no model calibrated, none selected, none promoted) |
| 8 | ``` |
| 9 | |
| 10 | ## What failed (M0 random walk, the simpler model) |
| 11 | - 50% interval covered 0.727 (band 0.46 to 0.54): far too wide in the middle. |
| 12 | - 95% interval covered 0.921 (band 0.93 to 0.97): slightly too narrow in the tails. |
| 13 | - Quarter 1 95% coverage 0.893 (band 0.90 to 0.99). |
| 14 | - One-step error 1166 mC against persistence (repeat last reading) 1162 mC: no gain over persistence. |
| 15 | - Passed: 80% coverage, bias (-0.0006), lag-1 autocorrelation (0.094), ten-step coverage (0.983). |
| 16 | - M1 constant velocity failed the same checks plus ten-step coverage (0.991, too wide), and its error was larger (1388 mC). |
| 17 | |
| 18 | ## Failure class (recorded by hand, as the protocol requires) |
| 19 | Non-Gaussian, heavy-tailed one-step changes: most steps move very little and a few move a lot, so one Gaussian noise level cannot be right in both the middle and the tails. This is a wrong noise shape (with possible switching between calm and bursty behaviour), not a wrong mean. In the protocol's own list of classes this maps to **model misspecification**, with regime switching as the secondary suspect. Review notes are in docs/estimation/reviews/. |
| 20 | - Quantization looks irrelevant (section 5a): the standard deviation of a one-step change is about 1159 mC against a 100 mC reading step. (Only 2.8% of innovations were exactly zero, but raw one-step changes are exactly zero 33% of the time, so that figure alone is weak evidence.) |
| 21 | - Not a wrong mean: bias and lag-1 autocorrelation passed. Autocorrelation beyond lag 1 is strong, though (Ljung-Box Q10 = 151 for M0 and 350 for M1, 5% cutoff about 18), so the noise shape and its persistence are both off. An independent recheck (fresh worker, own C recompute from the saved streams) reproduced all statistics and found no blocker or major issues. |
| 22 | - The regime split gave no information: every sample lies inside a load trial (idle n = 0). |
| 23 | - The M0 fit sat at the upper edge of the frozen q grid (q = 1e6), also on run A. The grid is frozen under v1 and was not widened. |
| 24 | |
| 25 | ## What this does and does not mean |
| 26 | - Under v1 rules the estimator is not promoted and nothing downstream may use its output as calibrated state. |
| 27 | - The failure stays as evidence. Bands, grid and models were not changed after seeing this result. |
| 28 | - Any follow-up is a new protocol version on fresh data (EST-3b, protocol section 7), for example a heavy-tailed noise model (Student-t or a two-level mixture) or a rate-aware model, entering only with this named failure class, as ADR 0020 section 2.4 requires. |