Interplane page as plain text, for reading tools and agents. English is the reference text: translate it with your own tool. Text in backticks and in ``` blocks (commands, fingerprints, file names) and link targets in <...> are exact: copy them, never translate them. Page: /drakestapleton/omega-mv/blob/main/docs/numeric/E1_C3_REDUCE_LDST_AB_ROUND1.md # omega-mv Omega: a language for verified programs, semantic identity and machine realization. Seed-born work and existing implementations have distinct provenance. Brought by drakestapleton Sign in to star 1 stars 0 watching About Files History Releases Proposed changes Issues For developers branch `main` Branches Tags History `omega-mv / docs / numeric / E1_C3_REDUCE_LDST_AB_ROUND1.md` 67 lines ยท 5140 bytes Raw Blame History Source # E1 C3 REDUCE LDST A/B, round 1 record Verdict, in the operator's words: bug not reproduced / comparison inconclusive (round 1 complete, rounds 2-5 not started). Script verdict line (log line 30): `E1 C3 REDUCE LDST AB: RUN_INCOMPLETE`, reason on log line 29: `incomplete because: quiet flag appeared before fix round 2`. Every number below is copied from the summary log. Line numbers refer to `~/workspace/test-queue-logs/E1N-C3AB-101051.log` (30 lines). ## What was compared Two builds of the same chip harness (`tests/test_omega_c3_ab_gb10.c`), run interleaved on the GB10 chip: - control arm: built with `-DOMEGA_C3_PROTECT_OFF`, which compiles out only the new reduce and load/store protection (GPU L2 flush plus a second release marker, step `marker2_wait`). - fix arm: the same sources with the protection compiled in. Built from omega `617971aa09c93649908e84e06cb681044d5bde41` (log line 1) and physics `e95e3ed2a86fe4bffe4d954fa94c27dfb5284280` (line 2). The PR head is now `44741c1b`, which adds a later diagnostics-only commit (marker2 late-arrival probe, stderr evidence) that touches `src/omega_numeric_reduce_gb10.c`; the chip run did not include it. Control binary sha256 `93ee1659a96ffed5e87228d7d63b32357a8efe068e52f207ec10ea00b2cc0972` (line 7). Fix binary sha256 `6c64ce80bceb7cdae0c26623ec756bdf7d050341db1398a51d0665fd0d024448` (line 8). ## Settings (line 6) `rounds=5 repeats=200 sizes=1000003,65 ops=SUM,MAX,MEAN,LDST`. Expected runs per arm if the whole plan had run: 4000 (line 28). Round 1 is 800 runs per arm (lines 14 and 21), so 1 of 5 planned rounds ran. ## Results, round 1 (lines 9, 10, 14-27) Qualifying-hit threshold fixed before the run: at least 10 unwritten-output hits in the control arm. A hit means the output was left unwritten (OMEGA_UNWRITTEN_TRAP). A device error (the chip call itself failed) is a refusal and is NOT a hit. Arm Runs Hits Device errors control (protection off) 800 1 11 fix (protection on) 800 0 6 Per operation: Op Control hits Control device errors Fix hits Fix device errors SUM 0 5 0 1 MAX 0 3 0 3 MEAN 0 3 0 2 LDST 1 0 0 0 total 1 11 0 6 Launcher failure lines by step (lines 20 and 27): - control: 11 x `GB10_DEVFAIL fn=run_chunk step=marker_wait drv_rc=-1` - fix: 6 x `GB10_DEVFAIL fn=run_chunk step=marker2_wait drv_rc=-1` The control arm has no `marker2_wait` step (its protection is compiled out), so the two arms fail at different waits by construction. This record draws no conclusion from the difference. ## How to read it - Control hits = 1, threshold = 10. The control arm did not reproduce the unwritten-output bug at the required rate, so the A/B cannot say anything about whether the protection fixes it. This is the "Known limits" case in the PR body. - Device errors are NOT counted as hits, in either arm. They are listed separately above. - The fix arm's 0 hits in 800 runs is NOT a proof of a fix. At the control arm's observed rate (1 hit in 800 runs) a build with no effect would be expected to show about 1 hit in 800 runs, so 0 of 800 does not separate the two arms. - The 11 control and 6 fix device errors are a separate open question (failed device calls, `drv_rc=-1`). They were not diagnosed here. - The threshold was not changed after seeing the data. ## Why it stopped Drake's rule (2026-10-02): finish round 1 untouched, stop at the round boundary only if the control arm ends below 10 qualifying hits. Stop-watcher log `~/workspace/test-queue-logs/e1-c3ab-stop-after-round1.log` (7 lines): - line 3, 12:10:50Z: control round 1 finished, `OMEGA_UNWRITTEN_TRAP: 1/800 device_errors=11`, qualifying hits 1, threshold 10. - line 4, 12:10:50Z: control below threshold, stop at the round boundary. - line 5, 12:10:50Z: waiting for fix round 1 to reach its last op (LDST); the next stop-watcher entry is 14:08:25Z. - line 6, 14:08:25Z: quiet flag raised (the stop mechanism). Line 7, 14:09:55Z: the script exited and the quiet flag dropped. The flag was up for 90 seconds. - The script then printed `RUN_INCOMPLETE` because the flag appeared before fix round 2 (log line 29). Round 1 had finished for both arms (log lines 9 and 10); rounds 2-5 were never started. ## Evidence paths - Summary log: `~/workspace/test-queue-logs/E1N-C3AB-101051.log`, sha256 `80801f6db509a530f76c60fdeac24223e7f103df70f82ebae5697ad068471264`. - Stop-watcher log: `~/workspace/test-queue-logs/e1-c3ab-stop-after-round1.log`, sha256 `f12a90e03860b5581ea80f0b0336607e42aa839ba57adb2fb44e1b217cd8d2f6`. - Transcript (outside the repo): `~/workspace/evidence-out/E1-C3-AB/ee2571feacd98b5252653c80dc65287d53ff1386145d525b563435896526f3a1.log`, sha256 `ee2571feacd98b5252653c80dc65287d53ff1386145d525b563435896526f3a1` (log lines 12 and 13). - Script: `~/workspace/scripts/lt-e1-c3-ab.sh` (outside the repo). ## Status This is the chip comparison, not the chip gate. The PR title keeps `[host NOT_RUN][chip NOT_RUN]`. No claim is made that the protection fixes the rc=-4 device errors. Rounds 2-5 remain not run.