TURING Yield energy protocol V0 (TY-4 measurement reuse, TY-5 concurrent attribution)
Update 2026-09-30: R16 is CLOSED (omega#112, 3dd5eaa, all gates G1 to G8 PASS) and the src/runtime/ edit freeze is LIFTED (aien-architecture #70, e89ba94). Statements below that the runtime is frozen "until R16" describe the state when this was written.
Status: PRE-REGISTERED. Committed and pushed before any timed run of stage 1 or stage 2.
Any change after data is seen is a dated amendment at the end of this file, committed before the run it affects.
Branch feat/turing-yield-ty45, base omega a927bd6. Date 2026-09-29.
1. Question
When two CPU workloads run at the same time, is the package energy of the pair different from the sum of their separate costs, and can an inspectable model built from independent signals predict the pair's energy without being fitted on it?
The identity I = E_AB - E_A - E_B + E_0 is algebra. Writing it down proves nothing. The evidence is:
- (a) a confidence interval on
Iover repeated, interleaved rounds, with a statement of whetherIis distinguishable from zero; - (b) an attribution model fitted from per-process PMU counters (independent of the energy meter) on idle and solo windows only, which predicts the energy of a held-out coalition (A+B) within stated uncertainty.
2. What is reused, what is new
- Meter and counters:
tests/runtime/r15_measure.{c,h}linked unchanged (frozen under R16; not edited).r15_energy_openis NOT called because it loads NVML (GPU driver library). The harness fillsR15Energy.hwmonitself after checking all tenaien_spbmchannel labels, initialises the mutex, and usesr15_energy_read,r15_energy_start_sampler(10 Hz) andr15_energy_samplesas they are. PMU:r15_pmu_open/start/stopper workload process (pid 0, inherit), so each process counts only its own threads. - Bad-window refusal:
tools/r15_reduce.cenergy_ok(spbm_ok and every overflow flag zero) and its monotonic rule (end reading >= start reading, else refuse; counters are never unwrapped). The TY reducer compilestools/r15_reduce.cinto its own translation unit (itsmainrenamed) and calls those functions; it does not copy them. The raw window records use the r15 JSONL writer (r15_rec_begin,r15_json_energy,r15_json_pmu). - New (C only):
tests/turing/ty_workload.c(workload process),tests/turing/ty_energy_window.c(measures one window per call),tools/ty_energy_reduce.c(reducer),src/turing/ty_energy.{c,h}(records, checks),tests/turing/test_ty_energy.c+ fixtures (hostile tests),tools/ty_energy_run.sh(rounds, idle wait, quiet flag),mk/turing_yield_energy.mk. - No GPU, no NVML, no src/runtime, no src/algebra edits (read-only use of
oma_rz_get/oma_rz_find).
3. Workloads (fixed)
- Operation: MA-2 ternary GEMV (Omega-X), shape m = 8192 rows, n = 16384 columns, weight sparsity 0.3, x uniform
int8. Weights and x are generated from a seed; every thread's plan is checked bit-exact against
oma_rz_oracleonce before the window. A failed check aborts the window. - Workload A:
R1_plain, seed 1. Packed weights 128 MiB per thread. - Workload B:
R2c_crumb, seed 2. Packed weights 32 MiB per thread. - Both are larger than the 8 MiB L3 of each cluster, so both stream from DRAM. A and B are different realizations so their counter mixes differ (untimed 2 s calibration on cpu 5: A retires about 3.3 instructions per cycle, B about 5; both move about the same bytes per second). This calibration was the only run before registration and set the shape; it was not metered.
- One process per workload, one pinned thread per listed core, each thread with its own packed copy. Threads call
runback to back until the process deadline (planned window length after GO). - X925 cores only: cpus 5-9 (cluster 0, L3 shared with A725 cpus 0-4) and 15-19 (cluster 1, L3 with 10-14). The window tool and its 10 Hz sampler are pinned to A725 cpu 0 so they never run on a measured core.
- Meter scope: all X925 cores are under one channel (
cpu_p).cpu_ptherefore cannot separate A from B. The per-participant signal for check (b) is the per-process PMU.
4. Conditions and order
Conditions per round: IDLE (no workload), A, B, AB (A and B started together). IDLE is a shuffled condition in every round, so each round has its own baseline; there is no fixed idle measured once.
Order: the four conditions are shuffled within each round by a seeded splitmix64 Fisher-Yates shuffle
(ty_energy_window --plan). The seed is recorded in the run manifest. Seeds: stage 1 0x7459510001,
stage 2 0x7459520001.
Per window: workloads are started and packed, all report READY, then a fixed 2 s settle, then the start reading, GO, the planned window, the end reading after every workload has exited. IDLE uses the same settle and length. Between windows the shell waits 3 s.
5. Stage 1: contention sweep (exploratory, selects the case)
Configurations (A cores | B cores):
| id | A | B | meaning |
|---|---|---|---|
| S1 | 5 | 6 | same L3, 1 + 1 core |
| S2 | 5 | 15 | cross L3, 1 + 1 |
| S3 | 5,6 | 7,8 | same L3, 2 + 2 |
| S4 | 5,6 | 15,16 | cross L3, 2 + 2 |
| S5 | 5,6,7 | 8,9 | same L3, 3 + 2 (all X925 of cluster 0) |
| S6 | 5-9 | 15-19 | cross L3, 5 + 5 (all X925) |
Window 10 s, 3 rounds per configuration, configurations in seeded shuffled order, rounds of one configuration together.
Contention score per configuration: for each round, slowdown s_X = 1 - calls_X(AB) / calls_X(solo) for X in {A, B};
round score (s_A + s_B) / 2; configuration score = mean over rounds.
Selection rule (fixed now):
- Contention case = the configuration with the highest score. It is called a REAL contention case only if its score is >= 0.05 AND every one of its rounds scores >= 0.02. Otherwise the result states "no contention case found" and stage 2 still runs on the highest-scoring configuration.
- Control case = the configuration with the lowest absolute score (a near-additive reference).
- Stage 1 energy numbers are reported as exploratory only.
6. Stage 2: confirmatory runs
For the contention case and the control case, in that order: 10 rounds of {IDLE, A, B, AB}, window 30 s (the audit's error budget needs >= 19 s for 1% resolution of I; 30 s gives margin). Duration about 24 min per case.
7. Recorded per window
Written as one r15-format JSONL record per window (kind":"ty_window"), raw files never overwritten:
- meter: start and end
R15EnergySample(energy_uj pkg, cpu_e, cpu_p, gpc_unverified, gpm; overflow_raw; power_uw; spbm_ok), window duration, all 10 Hz samples inside the window (t_ns, pkg, cpu_e, cpu_p), sample count, largest gap; - per workload: realization, cores, pinned, oracle check, planned and actual interval (GO, first and last thread times, exit), completed calls per thread, the six raw PMU counts per PMU with enabled and running times;
- machine: /proc/loadavg at both ends, per-cpu busy time deltas from /proc/stat (busy on cores not used by the window is the background load), scaling_cur_freq of all 20 cpus at both ends, all thermal zone temperatures at both ends, quiet flag present and whose, headroom of each energy counter to the 32-bit mJ wrap.
Meter facts recorded with the results: resolution 1 mJ step (readings end in 000 µJ) is not accuracy; sampling
10 Hz, sensor update about 0.1 s; 32-bit mJ counters wrap at about 4.29 MJ, flagged by overflow_raw; no external
calibration, so absolute accuracy is not claimed; gpc_unverified always reads 0 and is unused; observed variance is
reported per condition.
8. Validity (a window is refused, never repaired)
A window is refused if any of: SPBM unavailable or not ok at either edge; any overflow flag set; any energy counter decreased (r15_reduce rule, reused); a counter within one window's worth of the wrap; a gap between consecutive 10 Hz samples > 300 ms or fewer than 90% of the expected samples; a workload that failed the oracle check, was not pinned, exited early, or ran < 98% of the planned length (partial run); a workload interval not inside the meter window (interval mismatch); two windows whose meter intervals overlap; PMU running < 99.9% of enabled on the X925 PMU (multiplexed counts). A round with any refused window, or without its IDLE window, gives no I.
9. Normalisation and uncertainty
- Window energy
E_wper channel = (end - start) scaled to the planned length:E_w = dE * T_plan / dt. Channels: pkg, cpu_p, cpu_e, and rest = pkg - cpu_p - cpu_e (uncore and DRAM side). - Analytic edge bound per window: each edge is uncertain by up to one sensor period of power,
P_w * 0.1 s, uniform, so sdP_w * 0.1 / sqrt(3)per edge; for I, four windows and two edges each, combined in quadrature. - Empirical: the SD of I over valid rounds. This covers edges, drift and other tenants and is the one used for intervals. The analytic bound is reported next to it.
10. Check (a): interval on I
Per round r: I_r = E_AB - E_A - E_B + E_0 on each channel. Primary statistic: mean over valid rounds with 95%
Student-t interval (n - 1 degrees of freedom). Secondary: 95% bootstrap percentile interval of the mean
(splitmix64 seed 0x15, 10,000 resamples, same generator as r15_reduce). I is distinguishable from zero iff the
primary pkg interval excludes zero.
Check (a) PASSES (the measurement answers the question) iff >= 8 of 10 rounds are valid and the primary pkg interval
half-width is <= 2% of the mean E_AB pkg. The finding (zero, positive, negative) is stated separately from pass/fail.
11. Check (b): held-out coalition prediction
Model (fixed now), per window, pkg channel:
E_w = p0 * T_plan + a * CYC_w + b * INST_w
CYC_w, INST_w = sum over the window's workload processes of X925 PMU cpu_cycles and inst_retired
(0 for IDLE). Fit: ordinary least squares on every valid IDLE, A and B window of the case. Held out: every AB window
(never used in the fit). The fit reports its coefficients, residual SD s (n - 3 degrees of freedom) and the
condition number of the column-scaled design; above 1e4 the fit is DEGENERATE and check (b) FAILS.
Prediction for an AB window uses the counters measured in that AB window. Per-window 95% prediction interval
+- t * s * sqrt(1 + h), h the leverage.
Check (b) PASSES iff the fit is not degenerate, the 95% t-interval of the mean held-out error (observed - predicted) contains zero, AND at least 80% of held-out windows fall inside their prediction intervals.
Reported next to it (not pass/fail): the naive additive model E_A + E_B - E_0 (its error is exactly -I); the same
counter model on cpu_p; a variant with l2d_cache_refill in place of inst_retired.
12. Attribution records and conservation
Per valid AB window two attributions are built and checked:
- Solo counterfactual: idle share
E_0(COUNTERFACTUAL), AE_A - E_0, BE_B - E_0(COUNTERFACTUAL), remainder = measured - allocated. A remainder >= 0 is recorded UNATTRIBUTED. If allocated exceeds measured by more than the tolerance (1.96 x empirical SD of I, floored at the analytic edge bound) the attribution is REFUSED. - Counter model (only if check (b) passes): idle
p0 * T_plan(MODELLED), A and B from their own AB-window counters (COUNTER_DERIVED), remainder UNATTRIBUTED, same refusal rule.
The measured window total is DIRECT. Confidence scale and its mapping to physics FORGE V2 energy_source
(forge/v2/forge_substrate_v2.h, 3 levels), fixed in src/turing/ty_energy.h:
| TY confidence | meaning | FORGE V2 energy_source |
|---|---|---|
| DIRECT | read from the meter for exactly this interval and boundary | MEASURED (1) |
| COUNTER_DERIVED | a measured total split by measured per-participant counters | MEASURED (1) |
| CAUSAL_RUNTIME | split by the runtime's own causal record of who ran | ESTIMATED (2) |
| COUNTERFACTUAL | taken from a different window (solo or idle) | ESTIMATED (2) |
| MODELLED | from a fitted or cost model, not read for this interval | ESTIMATED (2) |
| UNATTRIBUTED | measured but assigned to nobody | NOT_MEASURED (0) |
COUNTER_DERIVED maps to MEASURED because FORGE has no finer level; the TY record keeps the finer label. FORGE is not changed.
Records use new digest domains turing.resource_interval.v0 and turing.resource_attribution.v0
(SHA-256(domain || 0x00 || OMG0 bytes), as in src/turing/field.c), integers only (µJ, ns). No existing turing.*
encoding or golden changes.
13. Quiet machine and safety
tools/ty_energy_run.sh runs detached (setsid nohup). Before each stage it waits until load1 < 2, no other make,
bench or qualify process runs, and ~/workspace/.spark-quiet is absent; then it creates its own quiet flag, runs
the stage, and removes the flag only if it is still its own. It never kills anything. Other tenants that start
later are recorded per window (background busy time), not hidden.
14. R16 loop inventory
The rounds, idle waits and the between-window pause live in shell (outside the R16 scanner's file types). The C files
hold only a deadline-bounded call loop and bounded for loops with none of the scanner's wait words, so they add no
loop-inventory site. Checked with tools/r16_loop_inventory.sh after coding; the result is recorded in the result
document.
Amendments
2026-09-29, before the first timed stage 1/2 run: Codex completed the interrupted
harness in an isolated worktree. Energy symbols use the ty_energy/TYE namespace
to coexist with TY-1. Hostile synthetic fixtures and sanitizer checks reject
malformed records, arithmetic overflow, missing sensors, counter wrap and failed
participants. The driver holds the existing .argus-bench.lock as well as its
owned quiet flag. Workloads, seeds, stage selection, fitting and qualification
thresholds above are unchanged. CI fixtures are synthetic and prove no hardware
energy result. No timed data has been used to tune this amendment.
2026-10-19, amendment 2, before any timed TY-4/TY-5 window (no data seen; ledger L109). The protocol cannot be followed as written on the box today, for three reasons found by inspection:
- No package meter. The
aien_spbmhwmon is not loaded on this boot (no/sys/class/hwmon/*/nameequalsaien_spbm). Loading it needs sudo, which agents do not use (handoff 2026-10-05-spbm-energy-operator-steps.md gives the operator steps).ty_energy_windowstill runs workloads and records PMU counts, timing and box state withmeter_ok: 0, but every window is refused for energy byty_energy_reduce, and stage 1's selection needs valid windows, so the reducer cannot select or compute I. - The quiet rule changed.
tools/ty_energy_run.shcreates the machine-wide~/workspace/.spark-quietflag and waits for load1 < 2. Agents may no longer raise that flag without Drake, and the shared box has not been below load 2 today (sensor log). The current mechanism isquiet-measure(holds off new builds) with the 20-minute rule (if the wait exceeds 20 minutes, run and record the load). - A new meter exists. Wall power from the UPS,
~/yardsticks/sensors/<date>.csv, one row every ~2 s, 10 W steps, whole UPS output (not the Spark alone).
What runs instead (TY-4/TY-5 wall amendment, "TYW"):
- Stage 1 is not run (its selection needs the package meter in the existing reducer). Two configurations are fixed now without data: S6 (A on cpus 5-9, B on 15-19: all ten X925 cores, both clusters, the largest power step the wall meter can see and the strongest DRAM sharing) as the contention candidate, and S2 (A on 5, B on 15: one core each, cross L3) as the near-additive control.
- Stage 2 as in section 6 but 3 rounds per configuration (not 10): IDLE, A, B, AB shuffled per round with
ty_energy_window --plan(seeds0x7459520001for S6,0x7459520002for S2), 30 s windows, 2 s settle, 3 s between windows,ty_energy_windowandty_workloadunchanged. The whole run is onequiet-measure spark-receipt tyw -- tools/ty_energy_wall_run.sh OUTinvocation. - Energy per window, wall channel:
E_w = mean UPS W over sensor rows inside [GO, GO + planned] x planned, with the window's monotonic GO time mapped to epoch time by an offset recorded by the driver right before each window (date +%s%Nbeside/proc/uptime, 10 ms resolution; the box does not suspend).tools/ty_energy_wall.ccomputes it; package energy is UNAVAILABLE and printed as such. - Per round
I_r = E_AB - E_A - E_B + E_0on the wall channel; mean over valid rounds with 95% Student-t interval (2 degrees of freedom, t = 4.303). A window is refused if a participant failed (ok,oracle_ok,pinned), if it has fewer than 10 sensor rows inside its 30 s, or if the offset cannot be read. Slowdownss_X = 1 - calls_X(AB) / calls_X(solo)are reported per round from the PMU-independent call counts. - Check (a), wall form: PASS iff all 3 rounds are valid and the 95% half-width of mean I_wall is <= 2% of mean E_AB wall. I is distinguishable from zero iff the interval excludes zero. Prediction: FAIL. Reason: the UPS meter steps by 10 W and other tenants on the shared box (load 5 to 25 today) move the wall draw by tens of watts between windows, against an expected AB step of about 30 to 60 W for S6, so the half-width of I will be several percent of E_AB or more; I for S2 is expected indistinguishable from zero.
- Check (b) is NOT RUN: the counter model has three parameters and 3 rounds give 9 fit windows on a meter whose noise is set by other tenants; a fit there would not test the attribution model. It waits for the package meter.
The hostile fixture tests (make test-turing-energy) are run unchanged and reported.