interplane.Get Omega
Read in your language

omega-mv

Omega: a language for verified programs, semantic identity and machine realization. Seed-born work and existing implementations have distinct provenance.

Brought by drakestapleton

branch main Branches Tags History

omega-mv / evidence / AT1 / 20261010T123939Z-ff81466-clock-shift / REPORT.md

28 lines · 3797 bytes Raw Blame History Source

AT-1 G8 follow-up item 4: shifted-system-clock control (and the sanitizer leg, by record)

Operator: AT-1 Agent 0 (Claude Code session 85679b2b), Spark only, 2026-10-10. Frozen candidate omega ff814662a19cf7da6b183f3e667c6c921e0ead21, the same fresh clone and the same three binaries as the item 2 run (baseline/binaries.sha256 equals clock-2028/binaries.sha256 and clock-2023/binaries.sha256). Evidence only, additive; nothing frozen was edited.

Shifted clock: what was done

AT1_RESULTS.md section 5 item 4 asks for "the same inputs under a clock set years apart". The system clock of the Spark was not changed (it serves other agents and TLS). Instead the whole qualification step (evaluator run.sh, the two shims, engine, oracle and evaluator binaries, the shims' date calls) ran under libfaketime, which interposes the C library clock calls (clock_gettime, time, gettimeofday) for every process in that tree, with the wall clock set to 2028-10-10 and, in a second run, to 2023-10-10. The provenance and toolchain queries of hidden_run.sh ran on the real clock (rustc --version deadlocks under libfaketime; the first attempt hung there and was stopped, nothing written). Tool: .

Proof the shift reached the components: every engine result file carries the shifted date (run_started_utc baseline 2026-10-10T12:30:06Z, 2028 run 2028-10-10T17:00:03Z, 2023 run 2023-10-10T17:00:03Z), and every oracle record likewise (clock-*/qualify-hidden/oracle/).

Result (COMPARISON.txt, produced by compare_clock.sh)

runhidden verdict_idhidden values blockpublic verdict_idpublic values blockevidence_digestrun_started year
clock 2028 vs realidentical 27/27identical 27/27identical 24/24identical 24/24differs 51/51shifted 51/51
clock 2023 vs realidentical 27/27identical 27/27identical 24/24identical 24/24differs 51/51shifted 51/51

Oracle records: identical apart from their two time lines and the digest, 27/27 in both runs. Evaluator gates printed in both runs: G1, G3, G4, G5 PASS, same counts as the real-clock run (positive 12, negative 12 public; positive 12, negative 15 hidden). This is the T9 rule of AT1_SPEC section 11 (identical case_id, acceptance_id, verdict_id and values block; evidence_digest must differ whenever the covered evidence bytes differ) measured under a clock years away rather than under a time-zone change only.

Sanitizer leg

The frozen Spark record already ran it: control C1-MODEL-TESTS in evidence/AT1/20261010T043603Z-3e18bd7/receipts/controls.tsv and evidence/AT1/20261010T044344Z-18e1786/receipts/controls.tsv reads "plain rc=0 (1390 passed, 0 failed); asan rc=0 (1390 passed, 0 failed)" (make test; make asan on the engine). The platform where it does not work is macOS 26.6.2 (AT1_RESULTS.md section 4 item 5); that remains a Mac limit, not a gap in coverage.

Claims, tagged