Interplane page as plain text, for reading tools and agents. English is the reference text: translate it with your own tool. Text in backticks and in ``` blocks (commands, fingerprints, file names) and link targets in <...> are exact: copy them, never translate them. Page: /drakestapleton/omega-mv/blob/main/evidence/OMEGA-NUMERIC-0/blobs/6976a3c48f0f3a720e31f93e8d926bdb7e5a334939ed96eef65016b7e623409c.stderr # omega-mv Omega: a language for verified programs, semantic identity and machine realization. Seed-born work and existing implementations have distinct provenance. Brought by drakestapleton Sign in to star 1 stars 0 watching About Files History Releases Proposed changes Issues For developers branch `main` Branches Tags History `omega-mv / evidence / OMEGA-NUMERIC-0 / blobs / 6976a3c48f0f3a720e31f93e8d926bdb7e5a334939ed96eef65016b7e623409c.stderr` 16 lines ยท 2290 bytes Raw Blame History 1 omega_gb10_execute_simt_op: refused before submission: variant LDS.U8 is not encoded for GB10: only the 32-bit LDS form is encoded (the old byte-wide words were never a round trip) 2 omega_gb10_execute_simt_op: refused before submission: variant STS.U8 is not encoded for GB10: only the 32-bit STS form is encoded (the old byte-wide words were never a round trip) 3 omega_gb10_execute_simt_op: refused before submission: variant LDS.S8 is not encoded for GB10: only the 32-bit LDS form is encoded 4 omega_gb10_execute_simt_op: refused before submission: variant LDS.U16 is not encoded for GB10: only the 32-bit LDS form is encoded 5 omega_gb10_execute_simt_op: refused before submission: variant STS.U16 is not encoded for GB10: only the 32-bit STS form is encoded 6 omega_gb10_execute_simt_op: refused before submission: variant LDS.64 is not encoded for GB10: only the 32-bit LDS form is encoded (no 64-bit register pair form) 7 omega_gb10_execute_simt_op: refused before submission: variant STS.64 is not encoded for GB10: only the 32-bit STS form is encoded (no 64-bit register pair form) 8 omega_gb10_execute_simt_op: refused before submission: variant LDS.128 is not encoded for GB10: only the 32-bit LDS form is encoded (no 128-bit form) 9 omega_gb10_execute_simt_op: refused before submission: variant STS.128 is not encoded for GB10: only the 32-bit STS form is encoded (no 128-bit form) 10 omega_gb10_execute_simt_op: refused before submission: variant SHFL_UP is not encoded for GB10: only SHFL.DOWN is encoded 11 omega_gb10_execute_simt_op: refused before submission: variant SHFL_BFLY is not encoded for GB10: only SHFL.DOWN is encoded 12 omega_gb10_execute_simt_op: refused before submission: variant SHFL_IDX is not encoded for GB10: only SHFL.DOWN is encoded 13 omega_gb10_execute_simt_op: refused before submission: variant REDUCE_MAX is not encoded for GB10: only the declared-order FP32 sum is encoded 14 omega_gb10_execute_simt_op: refused before submission: variant REDUCE_MIN is not encoded for GB10: only the declared-order FP32 sum is encoded 15 omega_gb10_execute_simt_op: refused before submission: variant REDUCE_SUM_BLOCK is not encoded for GB10: only the per-warp (32-lane) sum is encoded, not a CTA-wide one 16 omega_gb10_execute_simt_op: refused before submission: unknown numeric op 'FDIV_TYPO'