Interplane page as plain text, for reading tools and agents. English is the reference text: translate it with your own tool. Text in backticks and in ``` blocks (commands, fingerprints, file names) and link targets in <...> are exact: copy them, never translate them. Page: /drakestapleton/omega-mv/blob/main/spec/omegese-om2-errata.md # omega-mv Omega: a language for verified programs, semantic identity and machine realization. Seed-born work and existing implementations have distinct provenance. Brought by drakestapleton Sign in to star 1 stars 0 watching About Files History Releases Proposed changes Issues For developers branch `main` Branches Tags History `omega-mv / spec / omegese-om2-errata.md` 218 lines · 14464 bytes Raw Blame History Rendered 1 # OM-2 errata (coordinator L835) 2 3 Clarifications to the frozen `spec/omegese-om2.md` (sha256 ``245bb74e`…0881`) that resolve conflicts 4 inside it. No erratum changes the meaning of a construct that a lane has already built on. Each 5 erratum names who raised it. 6 7 ## E1 (AbiLane L837, 2026-10-25): which units are v2, and where identities live 8 9 §6 "Symbol versioning" and "Module boundary" conflicted with C2-style byte identity for v1 bindings. 10 Resolution: 11 - Every OM-2 unit (first non-note line `om2`) is bound ABI v2 (`omega2_`), whatever its 12 parameter kinds. This replaces "a unit with any unsized view or layout parameter". 13 - A v2 binding embeds the unit source sha256 (computed by the generator from the exact bytes), the omc 14 pin (supplied by the harness, per C3) and profile `OM-2`, readable via `omega2_ident_()`. 15 - OM-1 units stay ABI v1 with byte-identical binding output and no embedded identity. Their identity 16 (source sha256, omc pin, profile `OM-1`) is recorded by the harness, and `om/units.sh --check` refuses 17 a stale OM-1 unit. 18 - An `out` parameter is passed as one pointer with no count, like a layout. 19 20 ## E2 (QualPhaseB L836, 2026-10-25): sized arrays to unsized parameters 21 22 A sized array (length N) may be passed to an unsized `view T *` / `edit T *` parameter of a function 23 in either mode; `len` is N inside the callee. Writability rules are unchanged (a view never reaches an 24 edit). Unsized parameters are allowed on internal functions, not only on exported entries. 25 26 ## E3 (ShaLane L838, 2026-10-25): context copies and the C API names 27 28 - A byte copy of a context between `init` and `final` is an equivalent context: all hashing state lives 29 in the 104 layout bytes (no hidden state, no self-pointers). Receipt required: copy after k updates, 30 continue both copies with the same data, equal digests. Callers relying on this: 31 `src/fabric/fab_loopback.c:107`, `src/fabric/fabric.c:496`, `src/osh/host/osh_journal.c:81/104`. 32 - Digest overlapping data is used by `omega_program.c:777` and `tests/runtime/rx_sem_incremental.c:183`; 33 §6 `out` semantics cover it (receipt required). 34 - C API names: the SHA unit exports `omega2_sha256_init` etc. The bridge-generated header maps the 35 `sha256_*` names to them (generated, not handwritten). The freestanding nm allow-list 36 (`Makefile:657`, `RX_CX_FS_ALLOWED`) changes from `sha256_*` to the `omega2_sha256_*` symbols. That 37 one Makefile rule is changed by the SHA lane (L838) in the cutover commit. 38 39 ## E4 (QualPhaseB L836, 2026-10-25): diagnostic record fields and the fmt input 40 41 - `col` is the 1-based byte column of A on its line. 42 - The span `A-B` is the offending lexer token; at end of input it is the empty span `len-len`. 43 - `found` is the hex of the span bytes, or `-` when the span is empty. 44 - `expect` is the token class the parser wanted next. 45 - `om2 fmt`: "the rest" is the bytes after the first LF; the output does not contain the `om2 fmt` line. 46 47 ## E5 (ShaLane L838, 2026-10-25): scalar layout fields; cutover build rules 48 49 - In `field F T [COUNT] at OFF little|big`, an omitted COUNT is a scalar field (`get c F`, 50 `put c F v`). A COUNT (1..4096) is an array field (`get c F i`), even when COUNT is 1. In the §5 51 SHA example, `field count ulong 1 at 32 little` reads `field count ulong at 32 little` (scalar). 52 - Cutover: `src/omega_om_units.inc` is today included only by `src/sha256.c`, and BLAKE3 links through 53 it. The generated bindings move to a generated `src/omega_om_units.c`, and every build rule that 54 names `src/sha256.c` (Makefile, mk/*.mk, scripts) is switched to it in the cutover commit. The SHA 55 lane (L838) is the single writer of exactly those build-rule lines in that commit. 56 57 ## E6 (QualPhaseB L836, 2026-10-25): reserved names, diag fields, formatter edge cases 58 59 - **Q1:** declaring an OM-2 reserved word as a name inside an OM-2 unit (for example `fn rotr`) is 60 error 16, as OM-1 does for `fn break`. 61 - **Q2, `expect` and spans:** 62 - A lexically bad literal (error 6) or an out-of-range literal (error 8) reports `expect=number`. 63 - A missing `end` at end of input reports `expect=end`, with `sev=incomplete`. 64 - An unknown name reports `expect=name`. 65 - A line that ends before its operand when more input follows reports the LF byte as the offending 66 token (span covers the LF), with `sev=error`. 67 - An incomplete call to a function whose signature is not yet read reports the callee name token 68 as the span, with `sev=unknown`. 69 - **Q3:** line numbers always count every line of the whole input, the `om2 fmt` line included. 70 - **Q4, formatter:** 71 - (f) Formatter mode applies iff the input's first line, at byte 0, is exactly `om2 fmt`. A line 72 `om2 fmt` anywhere else is error 16. 73 - (c, d) A note line is any line whose first token is `note`, indented or not. It is kept byte for 74 byte, including its indentation and any trailing spaces. `text` literal bytes are kept byte for 75 byte. These two rules take precedence over every other formatting rule. 76 - (b) A whitespace-only line becomes an empty line. 77 - (a) Blank lines at the end of the input are error 6, so the formatter never removes lines and the 78 output always ends with exactly one LF after the last non-blank line. 79 - (e) The spacing next to `(` and `)` is kept as written. Grouping is never respaced. 80 - (g) CR is error 6 anywhere, including inside a `text` literal. 81 - (h) The rest may be an OM-1 unit. The formatter is lexical, and compile(fmt(x)) == compile(x) 82 applies whatever x's profile is. 83 84 ## E7 (QualPhaseB L836, 2026-10-25): unroll and inline limits, site records 85 86 - `for i T K unroll`: K = 0 or K > 64 is error 8. A K that is not a number is error 16. 87 - The limit of 64 copies applies per unrolled loop. Nested unrolls multiply, and their total is bounded 88 only by the 65536-word limit (error 14, `obligation=growth`). 89 - Inline depth: a call site in a function that is not being inlined is depth 1. A chain of 4 inlined 90 calls is accepted; a 5th level is error 14 (`obligation=growth`). 91 - `break`/`continue` inside a rolled loop nested within an unrolled body is allowed; it leaves the 92 rolled loop. Only a `break`/`continue` whose innermost loop is the unrolled one is error 9. 93 - `omc-site 1 line=N iter=P` records appear in emission order. P is the 0-based value of each enclosing 94 unrolled loop's counter, from outer to inner and joined by `.` (for example `iter=3.15`), or `-`. 95 - OM-1 shifts accept a shift amount of a different type. OM-2 `rotr`/`rotl` require the same type; 96 this stricter rule applies to OM-2 words only. 97 98 ## E8 (QualPhaseB L836, 2026-10-25): codes and lines for §5/§6 refusals 99 100 - A `fresh` with N > 64 is error 14 (`obligation=init`). 101 - An abstract type used as an entry parameter or return, or as an array element type, is error 7. 102 - An operation on an abstract value that its `abstract` line does not list is error 7. 103 - A field access with the wrong arity: a missing index on an array field (any COUNT) is error 4; an 104 extra index on a scalar field is error 5. 105 - Layout SIZE 0 or > 4096, and a `layout` after the first `fn`, are error 29 (`obligation=layout`). 106 - `part` anywhere other than as a call argument is error 9. 107 - Which line each error names: 108 - error 27: the offending `get` or call line; 109 - error 28: the `seal` line, or the `holds` line for a bad predicate; 110 - error 29: the offending `field` line, or the `layout` line for a SIZE error. 111 - Confirmed as written: 112 - `rotr` of a dup32 value with n = 64 traps 7; 113 - `omc-check` records name the constructor's `ret seal` line; 114 - for layout fields, a constant out-of-range index is error 21, a `put` through a view is error 20, 115 and an array of the wrong size is error 7. 116 117 ## E9 (QualPhaseB L836, 2026-10-25): rotate count of an abstract value; late layout line 118 119 - For `rotr`/`rotl` on an abstract value, `n` has the abstract type's representation type T (ulong 120 for dup32), so a bare number takes T. 121 - Error 29 for a `layout` after the first `fn` names the `layout` line. 122 123 ## E10 (QualPhaseB L836 D3, 2026-10-25): blank lines before `om2` 124 125 A unit is OM-2 iff its first line that is neither a `note` line nor blank (empty, or only spaces) is 126 exactly `om2` (or `om2 diag`). OM-1 refuses such a unit at the `om2` line whether or not blank lines 127 precede it, so C1 and C3 hold. The fmt mode rule (E6 Q4 f, the first line at byte 0) is unchanged. 128 129 ## E11 (QualPhaseB L836, 2026-10-25): leakage scan wording and public memory 130 131 - §8 evidence (a): a static scan cannot show that a branch is never taken. The requirement reads 132 instead: "a data-dependent conditional branch must branch only to a trap stub (a check such as the 133 uint conversion range check after `and x 0xffffffff`), and is listed." 134 - The context's `count` field (bytes 32..39) encodes the number of bytes absorbed so far, which the 135 leakage model treats as public (a length). The scanner takes an explicit, reviewable public-memory 136 declaration `pub:SLOT:OFF:LEN` (for SHA: the context slot, bytes 32..39). Items derived only from 137 declared public memory are classified as length-dependent. Every declaration is listed in the 138 evidence. 139 140 ## E12 (advisor review, 2026-10-25): supersedes the first bullet of E11 141 142 A trap destination alone does not establish trace equivalence: a reachable trap whose condition 143 depends on secret data changes the trace (`fn f a view ulong 4 to uint / ret uint get a 0 / end` 144 exits 0 for input 0 and 105 for input 2^32). A data-dependent conditional branch counts as 145 length-dependent only when its trap edge is shown unreachable by a stated static rule. In OM-2 that 146 is only the known-bits rule: the operand of a conversion range check is the result of `and x M`, with 147 M a constant that fits the target type. Every other data-dependent branch, trap stub or not, is 148 reported `MANUAL`. A unit with any `MANUAL` item gets the verdict NOT_RUN for trace equivalence, never 149 PASS. The counterexample above is a required negative control (expected: MANUAL / NOT_RUN). E11's 150 public-memory declaration stands. 151 152 ## E13 (advisor review, 2026-10-25): a public-memory declaration needs public stores 153 154 A `pub:SLOT:OFF:LEN` declaration makes a load length-dependent only if every store the unit can make 155 into that range stores a value that is itself length-dependent (derived from lengths, counts, the op 156 code, constants or declared-public loads). A store into a declared-public range of a data-dependent or 157 unclassified value makes every later load from that range data-dependent, or `MANUAL` when the 158 scanner cannot order the store and the load. Required negative control: 159 `fn f c edit uchar 104 a view uchar 1 to ulong / put c 32 get a 0 / if eq get c 32 0 / ret 0 / else / 160 ret 1 / end / end` with `pub:0:32:8`. Expected: MANUAL or data-dependent, NOT_RUN; natively, message 161 bytes 0 and 1 give exits 0 and 1. 162 163 ## E14 (advisor review, 2026-10-25): expansion work fuel 164 165 The emitted-word cap alone does not bound compiler work. Nested unrolls of a body that emits nothing 166 (`for a ulong 64 unroll` four deep around `note empty`) emit an identical 212-byte artifact at every 167 depth, yet re-parse 64^4 bodies (1.58 s with omc `c23b3376` against about 1 ms at depth 1). The §4 168 sentence "each bound limits compiler work and memory linearly in the output" is withdrawn and 169 replaced by: 170 - Every function has an expansion fuel of 65536. Each copy of an unrolled body and each inline 171 expansion costs 1, at every nesting depth, so nested unrolls multiply their cost. Exhausting the fuel 172 is error 14 (`obligation=growth`) at the line of the loop or call that exhausted it. 173 - With fuel F, compiler work is then bounded by O(F x the source length of the function) re-parsed 174 tokens, plus the OM-1 capacities. 175 - Required controls: 176 - depth 2 of 64-copy empty unrolls (4096 copies) compiles; 177 - depth 3 (262144 copies) is error 14; 178 - the compile time of the largest accepted case is reported. 179 180 ## E15 (CompilerS3 L834, 2026-10-25): S3 points the contract did not settle (accepted) 181 182 1. `abstract` and `holds` lines are accepted only before the first `fn`; after it they are error 9. 183 2. `holds X dup32` with X of base type uint is error 28 (dup32 needs ulong). 184 3. A bad base type in `abstract` is error 7; an unknown word after `ops` is error 16. 185 4. Layout fields accept every integer type; signed fields are sign-extended on read. 186 5. A layout parameter is also a plain `uchar` array of SIZE bytes (`get c i`, `len c`) when the word 187 after it is not one of its fields. A field name therefore shadows a local of the same name in that 188 position. 189 6. A `note` line inside a constructor body makes the body not exact, so the runtime check is kept. 190 7. A missing index or value is error 4 reported on the next line (OM-1 behaviour). E8 fixes the lines 191 only for errors 27, 28 and 29. 192 193 ## E16 (QualPhaseB L836, 2026-10-25): when fuel is charged 194 195 Fuel (E14) is charged in source/emission order. An unrolled loop is charged K units when it starts, at 196 its own line, before any copy is expanded. An inline expansion is charged 1 when it starts, at the call 197 line. Error 14 names the line of the construct whose charge exceeds the fuel. 198 199 ## E17 (CompilerS4 L834, 2026-10-25): S4 points the contract did not settle (accepted) 200 201 1. `export` together with `fn main` is error 9. 202 2. A 33rd export is error 14. 203 3. `export` not followed by `fn`, or inside a function body, is error 16. 204 4. An `out T N` parameter is an `edit T N` in every function, internal ones included. `out T *` and 205 `out … fresh` are error 16. 206 5. A part may be passed only to an unsized parameter; passing it to a sized one is error 7. 207 6. The base of a part must be a name, so a part of a part is error 9. 208 7. The six-slot limit (§4) also applies in program mode. 209 8. Inline functions are also compiled standalone, in source order, each with its own fuel (E14/E16). 210 The fuel error therefore reports the first function in source order that runs out. 211 212 ## E18 (advisor review, 2026-10-25): no gate widening at cutover (supersedes E3 item 3) 213 214 The compatibility wrappers `sha256_*` (status ≠ 0 → abort) are generated as out-of-line definitions in 215 `src/omega_om_units.c` (bridge output `apic`). `src/omega_api_decl.h` (output `apih`) carries 216 prototypes only. The freestanding `rx_cortex.o` therefore keeps exactly main's undefined symbols, and 217 Makefile `RX_CX_FS_ALLOWED` is not changed. Adding `abort` or `omega2_*` to that list is refused, 218 because it would weaken the freestanding gate.